Dova Heights

PROVISION OF ACOUSTIC LEAK INSPECTION FOR PIPELINE INSPECTION

CLIENT
PROJECT NAME:
PROVISION OF ACOUSTIC LEAK INSPECTION FOR PIPELINE INSPECTION
LOCATION
OML 123 – OFFSHORE NIGERIA
STRUCTURE TYPE
FLOWLINE WITH 16” FLANGES
PERIOD
2013
INSPECTION MODE
DIVER
SUMMARY:
Deployment of the Acoustic Leak Detection (ALD) System in Diver hand-held mode using point inspection techniques to inspect for leak on flanges during tightening. Scope of work included inspection for eventual leaks on the flowline (water depth – 15m) and a test pressure of 10bars.